BTUSizing

What size heat pump do I need?

Both loads, the one that decides the size, and the shortfall a cold climate leaves.

Your space

Common sizes

A heat pump has to do two jobs with one piece of equipment, and the two loads are rarely the same size. Which one wins depends on where you live, and that single fact explains most of the confusion about heat pump sizing.

Before you buy anything. This is a square-foot estimate, not an ACCA Manual J load calculation. A Manual J uses your building’s real construction, orientation and air leakage, and on a well-sealed house it usually comes out smaller than this. Use this to sanity-check a quote, not to replace one.

What a Manual J actually measures.

Worked example: 2,000 sq ft in climate zone 5

Zone 5 is Chicago, Denver, Boston and Detroit. Four occupants, kitchen inside the conditioned area, average insulation, 8 ft ceilings.

Cooling load47,450 BTU (4.0 ton)
Heating load77,500 BTU
Which drives the sizeHeating
Unit sized to the cooling load48,000 BTU
Heating that unit cannot cover at design temperature29,500 BTU

In zone 5 the heating load is the larger of the two, so a heat pump sized purely for cooling leaves 29,500 BTU uncovered on the coldest design day. That gap is what supplemental heat exists for: electric resistance strips, a gas furnace in a dual-fuel setup, or a cold-climate heat pump that holds more of its capacity at low outdoor temperatures.

Sizing a heat pump to heating instead

The tempting fix is to size the equipment to the heating load and be done with it. In a cold climate that oversizes the cooling side badly, and you get the short-cycling and humidity problems described on the oversizing page every summer.

The three conventional answers, in the order most contractors consider them:

  1. Size to cooling, add supplemental heat. The default. Cooling behaves correctly all summer and the strips or furnace cover the coldest days.
  2. Use a variable-capacity (inverter) unit. These modulate down, so a unit large enough for the heating load can still run gently in cooling. This is the main reason inverter-driven equipment took over in cold climates.
  3. Dual fuel. Heat pump above the balance point, gas furnace below it.

Heating and cooling load by climate zone

For a 2,000 sq ft house with average insulation and 8 ft ceilings, so the only thing changing is the climate:

Design loads for a 2,000 sq ft house by DOE climate zone
ZoneCoolingHeatingDriven byExample cities
163,75037,500CoolingMiami, Key West, Honolulu
256,25047,500CoolingHouston, Orlando, Phoenix, New Orleans
350,25057,500HeatingAtlanta, Dallas, Los Angeles, Charlotte
446,25067,500HeatingWashington DC, Seattle, St Louis, Nashville
542,25077,500HeatingChicago, Denver, Boston, Detroit
639,00087,500HeatingMinneapolis, Burlington, Helena
735,00097,500HeatingDuluth, Grand Forks, International Falls
832,250107,500HeatingFairbanks, Barrow

The crossover sits in zone 4: south of it a house is cooling-driven, north of it heating-driven. That is the single most useful line in this table.

Frequently asked questions

What size heat pump do I need for a 2,000 square foot house?
In climate zone 5 the cooling load is about 47,450 BTU and the heating load about 77,500 BTU, so a 48,000 BTU unit sized to cooling with roughly 29,500 BTU of supplemental heat. The answer changes substantially with climate zone, insulation and ceiling height.
Should a heat pump be sized for heating or cooling?
Conventionally for cooling, with supplemental heat covering the coldest days, because a unit sized to a cold-climate heating load will be badly oversized in summer and will short cycle. Variable-capacity inverter equipment relaxes this, because it can modulate down far enough to cool properly at a larger nominal size.
What is the balance point of a heat pump?
The outdoor temperature at which the heat pump output exactly matches the building heat loss. Above it the heat pump carries the house alone; below it supplemental heat makes up the difference. The colder the climate and the smaller the unit, the higher the balance point sits.
Do heat pumps work in cold climates?
Yes, and modern cold-climate models hold useful capacity well below freezing, but capacity does fall as it gets colder. That is why the heating shortfall is worth calculating rather than assuming, and why supplemental heat is part of the design rather than an admission of failure.